Aktivität
von 15.10.2022 bis 13.11.2022
02.11.2022
- 10:48 Feature #295 (Erledigt): have an alias name for the device
- 10:48 Feature #295 (Erledigt): have an alias name for the device
- Show either the serial number or the device alisa name on the display.
- 10:47 Feature #293 (Erledigt): Bringup: add calibration measurement functions
- 10:46 Fehler #279 (Erledigt): ADC breaks after buzzer alarm
- It was the STOP mode in delay() which reseted periphery.
29.10.2022
- 17:48 Feature #293: Bringup: add calibration measurement functions
- Actually not needed but implemented.
The values are quite close.
Serno.1: 4031
Serno.2: 4029
28.10.2022
- 14:42 Fehler #279: ADC breaks after buzzer alarm
- This can be added to bringup tests.
- 14:39 Feature #293 (Erledigt): Bringup: add calibration measurement functions
- Device should be able to calibrate itself and store the values in eeprom.
25.10.2022
- 10:57 Fehler #286 (Abgewiesen): ADC breaks after buzzer alarm
- Duplicate
15.10.2022
- 11:20 Fehler #279: ADC breaks after buzzer alarm
- return ADC value 0 and set heartbeat led to error blinking.
- 11:19 Fehler #286 (Abgewiesen): ADC breaks after buzzer alarm
- Reason unclear.
At least the "trouble"-mechanism of sensemux could be used to indicate the problem via LED.
Assum... - 10:46 Fehler #283 (Erledigt): SPI Flash not working
- Error in App-file; CS was not used.
Auch abrufbar als: Atom