Aktivität
von 02.12.2021 bis 31.12.2021
14.12.2021
- 14:27 Fehler #110: Replace buzzer
- MOSFET will probably arrive in CW50.
Lets see if it will help.
The Transistor variant works with 2V (current unknow...
13.12.2021
- 14:24 Feature #109: Implement HWData
- Its Software
- 13:12 Feature #114 (Erledigt): Device must run with 2Volts
- The white LED probably has to be replaced.
-The violet led was not so picki (The one at the debug board can be ens...
10.12.2021
- 12:47 Fehler #110: Replace buzzer
- The 60V specified NMOS is not good.
Better use an LGE2300-LGE; Specification is 9A at VGS=3,0V and VDS=3,0V, ca. 40m...
09.12.2021
- 15:21 Fehler #110 (Erledigt): Replace buzzer
- The buzzer is not loud enough.
Its ok when running at 3V3;
Use another one with rated 3V: LD-BZEL-T30-0802
But...
07.12.2021
- 17:35 Feature #109 (Abgewiesen): Implement HWData
- 17:35 Feature #109 (Abgewiesen): Implement HWData
- Store it via campo-scripts.
Show them via libcampo
02.12.2021
Auch abrufbar als: Atom