- 14:47 mainSwitch Fehler #434 (Abgewiesen): Power supply on CANBus is very poor
- Duplicate
- 11:58 mainSwitch Fehler #434 (Abgewiesen): Power supply on CANBus is very poor
- The traces are only 0.2mm
"Link":https://www.leiton.de/leiton-tools-spannungsabfall-leiterplatten.html - 12:01 mainSwitch Fehler #435 (Neu): Power supply on CANBus is very poor
- The traces are only 0.2mm
"Link":https://www.leiton.de/leiton-tools-spannungsabfall-leiterplatten.html
Sollte eig...
06.11.2023
- 16:47 Rufa Feature #431 (Neu): Introduce more noise filtering
- Add ferrit beans to power lines and to TC-wires.
- 16:35 CANBridge Fehler #430 (Erledigt): Transceiving is super slow and errornous
- Looks like the default frequencies are completely wrong. They have to be set according to the 868Mhz.
Maybe the data...