TDT-Protocol on CAN » Historie » Version 95
Maximilian Seesslen, 11.07.2023 16:21
1 | 12 | Maximilian Seesslen | h1. Intro |
---|---|---|---|
2 | 1 | Maximilian Seesslen | |
3 | 95 | Maximilian Seesslen | With the TDT-Protocol sensors can send their values on the BUS without necessarily knowing about complex object catalogue. |
4 | An monitor-software is able to display sensor values of nodes without knowing anything about the sensors or their configuration. |
||
5 | An XML file can be used for supplement for an monitor software. |
||
6 | The CANId consists of an function code and the node id. Like CANOpen the function code is 4 Bits and the Node-ID is 7 Bit. |
||
7 | 46 | Maximilian Seesslen | In CAN2.0A there can only be 128 Nodes. |
8 | 1 | Maximilian Seesslen | |
9 | 35 | Maximilian Seesslen | CAN 2.0A: 0..0x7FF |
10 | CANOpen: 4 Bit Function code, 7 Bit Node-ID |
||
11 | Node-Id: 0..0x7F |
||
12 | 1 | Maximilian Seesslen | Function-Code Mask: 0x780 |
13 | 46 | Maximilian Seesslen | There are 14 or 28 Filters on STM32Fs |
14 | Some STM32 have an internal 96-bit unique ID. |
||
15 | 1 | Maximilian Seesslen | |
16 | 74 | Maximilian Seesslen | |_. Bits |_. Area |_. Decription |_. Examples | |
17 | 73 | Maximilian Seesslen | | 4 |/2.CAN-Id | Function code | Send object | |
18 | 74 | Maximilian Seesslen | | 7 | NodeId | Sensemux WZ | |
19 | | 16 |/4.Data | Object | Set illumination | |
||
20 | | 8 | Unit | promilPwm | |
||
21 | | 8 | Flags | Confirmation required | |
||
22 | | 32 | Value | 350‰ | |
||
23 | 92 | Maximilian Seesslen | | 64Bits Data| | | | |
24 | 71 | Maximilian Seesslen | |
25 | 87 | Maximilian Seesslen | [[NMT]] |
26 | [[MMP]] |
||
27 | 89 | Maximilian Seesslen | [[Alerts]] |
28 | 87 | Maximilian Seesslen | |
29 | 44 | Maximilian Seesslen | h2. Function code |
30 | 86 | Maximilian Seesslen | |
31 | 83 | Maximilian Seesslen | Function code can be 0..15 / 0x00..0x0F |
32 | 44 | Maximilian Seesslen | |
33 | 1 | Maximilian Seesslen | |_. Code |_. Decription |_. Examples | |
34 | 51 | Maximilian Seesslen | | 0x0 | NMT-Write | | |
35 | 1 | Maximilian Seesslen | | 0x1 | NMT-Send | | |
36 | 79 | Maximilian Seesslen | | 0x2 | NMT-Introduce | Device sends UID only | |
37 | 82 | Maximilian Seesslen | | 0x3 | NMT-setId | Set NodeId on Device | |
38 | 90 | Maximilian Seesslen | | 0x4 | Alarms | Send by nodes | |
39 | 82 | Maximilian Seesslen | | 0x5 | Write object | Set Date, illumination | |
40 | | 0x6 | Read object | Get product codes | |
||
41 | | 0x7 | Send object | Send temperature | |
||
42 | | 0x8 | Resend object | Replay recorded data | |
||
43 | 58 | Maximilian Seesslen | | 0x9 | data blob | | |
44 | 1 | Maximilian Seesslen | |
45 | 94 | Maximilian Seesslen | h2. Node-ID |
46 | |||
47 | Depending on the function code, the Node-ID can be the target or the source. Node-ID '0' means every node should inspect the message. |
||
48 | |||
49 | |_. Function code |_. Node-ID interpretation| |
||
50 | | NMT-Write | Destination or 0 | |
||
51 | | NMT-Send | Source | |
||
52 | | NMT-Introduce | Source | |
||
53 | | NMT-setId | New Node-ID | |
||
54 | | Alarms | Source | |
||
55 | | Write object | Destination or 0 | |
||
56 | | Read object | Targeted Source | |
||
57 | | Send object | Source | |
||
58 | | Resend object | Replayed Source | |
||
59 | | data blob | Destination | |
||
60 | |||
61 | 1 | Maximilian Seesslen | h1. IDs, ranges and commands |
62 | |||
63 | 46 | Maximilian Seesslen | h2. Node IDs |
64 | 1 | Maximilian Seesslen | |
65 | 44 | Maximilian Seesslen | * 11-Bit-Identifier, (CAN 2.0A); 2048; 0x0 ... 0x7F0; 0x0 ... 0x7F with function code |
66 | 1 | Maximilian Seesslen | * 29-Bit-Identifier, (CAN 2.0B); 0x20000000 |
67 | |||
68 | |_. Range |_. Decription |_. Examples | |
||
69 | | 0x01-0x0F | Network Manager | PC | |
||
70 | | 0x10-0x2F | Active controller | CANDis | |
||
71 | | 0x30-0x4F | Actor | CANSwitch | |
||
72 | 47 | Maximilian Seesslen | | 0x50-0x6F | Sending sensors | Sensemux, CANIO | |
73 | 1 | Maximilian Seesslen | | 0x70-0x7F | Passive Sensors | CANRec | |
74 | |||
75 | 75 | Maximilian Seesslen | h2. CAN data structutre |
76 | 1 | Maximilian Seesslen | |
77 | 68 | Maximilian Seesslen | |_. Size |_. Decription |_. Examples | |
78 | 75 | Maximilian Seesslen | | 2 | Object | Set ambient illumination | |
79 | 1 | Maximilian Seesslen | | 1 | Unit | hz, Float, Time, Date, Percent, promilPwm, centiCelsius, canId, room, Multipacket-String | |
80 | 93 | Maximilian Seesslen | | 1 | Flags | Confirmation required | |
81 | 68 | Maximilian Seesslen | | 4 | Value | The kind of data that was specified in 'unit' | |
82 | 36 | Maximilian Seesslen | |
83 | 44 | Maximilian Seesslen | h2. Objects |
84 | 36 | Maximilian Seesslen | |
85 | 59 | Maximilian Seesslen | |_. Code |_. Description | |
86 | | none | | |
||
87 | | ambientLight | | |
||
88 | | plantLight | | |
||
89 | | multimediaSwitch | | |
||
90 | | mainSwitch | | |
||
91 | | date | | |
||
92 | | time | | |
||
93 | | dummy | | |
||
94 | | plantSensor | | |
||
95 | | plantSensor [0-7] | | |
||
96 | | firmwareVersion | | |
||
97 | | firmwareDate | | |
||
98 | | hardwareRevision | | |
||
99 | | hardwareDate | | |
||
100 | | temperatureIntern [0-7] | | |
||
101 | 64 | Maximilian Seesslen | | temperatureExtern [0-7] | | |
102 | 59 | Maximilian Seesslen | | humidity | | |
103 | | VOC | | |
||
104 | 60 | Maximilian Seesslen | | Replay | | |
105 | 63 | Maximilian Seesslen | | Data-Dump (SD-Card) | | |
106 | 1 | Maximilian Seesslen | |
107 | 44 | Maximilian Seesslen | h2. Units |
108 | 17 | Maximilian Seesslen | |
109 | 44 | Maximilian Seesslen | * Date: year 2B, month 1B, day 1B |
110 | 1 | Maximilian Seesslen | * Time: hour 1B, minute 1B, second 1B, subsecond 1B |
111 | 17 | Maximilian Seesslen | |
112 | 46 | Maximilian Seesslen | h2. Example: Turn on the lights |
113 | 1 | Maximilian Seesslen | |
114 | 46 | Maximilian Seesslen | |_.Data |_.Size |_.Description | |
115 | |0x300 | 29 Bits | Function code: Write Object; All objects. | |
||
116 | 91 | Maximilian Seesslen | |0x0 | 2 Byte | Object: Ambient illumination | |
117 | 67 | Maximilian Seesslen | |0x1 | 1 Byte | Data-Type: PWM Permill | |
118 | 1 | Maximilian Seesslen | |0x1 | 1 Byte | Flags: None | |
119 | 70 | Maximilian Seesslen | |1000 | 4 Byte | Value: Full Brightness | |