Projekt

Allgemein

Profil

TDT-Protocol on CAN » Historie » Version 59

Maximilian Seesslen, 13.02.2023 14:55

1 12 Maximilian Seesslen
h1. Intro
2 1 Maximilian Seesslen
3 17 Maximilian Seesslen
With the TDT-Protocol sensors can just send their values on the BUS without complex object catalogue.
4
An monitor-software is able to display values without knowing anything about the sensors or their configuration.
5 46 Maximilian Seesslen
The CANId cinsists of an function code and the node id. Like CANOpen the function code is 4 Bits and the Node-ID is 7 Bit.
6
In CAN2.0A there can only be 128 Nodes.
7 1 Maximilian Seesslen
8 35 Maximilian Seesslen
CAN 2.0A: 0..0x7FF
9
CANOpen: 4 Bit Function code, 7 Bit Node-ID
10
Node-Id: 0..0x7F
11 1 Maximilian Seesslen
Function-Code Mask: 0x780
12 46 Maximilian Seesslen
There are 14 or 28 Filters on STM32Fs
13
Some STM32 have an internal 96-bit unique ID.
14 1 Maximilian Seesslen
15 44 Maximilian Seesslen
h2. Function code
16
17 1 Maximilian Seesslen
|_. Code |_. Decription    |_. Examples             |
18 51 Maximilian Seesslen
| 0x0    | NMT-Write       |                        |
19
| 0x1    | NMT-Send        |                        |
20
| 0x2    | Alarms          |                        |
21 58 Maximilian Seesslen
| 0x3    | Write object    | Set Date, illumination |
22
| 0x4    | Read object     | Get product codes      |
23
| 0x5    | Send object     | Send temperature       |
24
| 0x6    | Resend object   | Replay recorded data   |
25
| 0x7    | data blob       |                        |
26
27 1 Maximilian Seesslen
28
h1. IDs, ranges and commands
29
30 46 Maximilian Seesslen
h2. Node IDs
31 1 Maximilian Seesslen
32 44 Maximilian Seesslen
* 11-Bit-Identifier, (CAN 2.0A); 2048; 0x0 ... 0x7F0; 0x0 ... 0x7F with function code
33 1 Maximilian Seesslen
* 29-Bit-Identifier, (CAN 2.0B); 0x20000000
34
35
|_. Range      |_. Decription           |_. Examples              |
36
| 0x01-0x0F    | Network Manager        | PC                      |
37
| 0x10-0x2F    | Active controller      | CANDis                  |
38
| 0x30-0x4F    | Actor                  | CANSwitch               |
39 47 Maximilian Seesslen
| 0x50-0x6F    | Sending sensors        | Sensemux, CANIO         |
40 1 Maximilian Seesslen
| 0x70-0x7F    | Passive Sensors        | CANRec                  |
41
42 45 Maximilian Seesslen
h2. Object structutre
43 1 Maximilian Seesslen
44 44 Maximilian Seesslen
|_. Size |_. Decription |_. Examples                                                       |
45
| 2      | Object       | Plain Sensor value; Set illumination                             |
46
| 1      | Data type    | Int, Float, Time, Date, Percent, Promil, Multipacket-String      |
47
| 1      | Unit         | Hz, °C, Time, Date, PWM, CAN-ID, Name, Description, Room         |
48
| 4      | Value        | 32Bit                                                            |
49 36 Maximilian Seesslen
50 44 Maximilian Seesslen
h2. Objects
51 36 Maximilian Seesslen
52 59 Maximilian Seesslen
|_. Code                  |_. Description             |
53
| none                    |                           |
54
| ambientLight            |                           |
55
| plantLight              |                           |
56
| multimediaSwitch        |                           |
57
| mainSwitch              |                           |
58
| date                    |                           |
59
| time                    |                           |
60
| dummy                   |                           |
61
| plantSensor             |                           |
62
| plantSensor [0-7]       |                           |
63
| firmwareVersion         |                           |
64
| firmwareDate            |                           |
65
| hardwareRevision        |                           |
66
| hardwareDate            |                           |
67
| temperatureIntern [0-7] |                           |
68
| temperatureExtern       |                           |
69
| humidity                |                           |
70
| VOC                     |                           |
71
72
73 1 Maximilian Seesslen
74 44 Maximilian Seesslen
h2. Units
75 17 Maximilian Seesslen
76 44 Maximilian Seesslen
* Date: year 2B, month 1B, day 1B
77 1 Maximilian Seesslen
* Time: hour 1B, minute 1B, second 1B, subsecond 1B
78 17 Maximilian Seesslen
79 46 Maximilian Seesslen
h2. Example: Turn on the lights
80 1 Maximilian Seesslen
81 46 Maximilian Seesslen
|_.Data   |_.Size   |_.Description                              |
82
|0x300    | 29 Bits | Function code: Write Object; All objects. |
83
|0x0      | 2 Byte  | Message-Type: Global command              |
84
|0x1      | 1 Byte  | Data-Type: Permill                        |
85
|0x1      | 1 Byte  | PWM: PWM permilli                         |
86
|1000     | 4 Byte  | Value: Full Brightness                    |
87
88 1 Maximilian Seesslen
h1. Multipacket-Strings
89
90 46 Maximilian Seesslen
There should be the posssibillity to write the complete SPI-Flash even if it takes forever.
91
Not every slave needs to be able to send super big blocks. But every slave should be able to
92
send e.g. descriptions.
93 15 Maximilian Seesslen
94 46 Maximilian Seesslen
|_. Size    |_. Type                                           |
95
| 0x4       | Package number (0: Data contains package count)  |
96
| 0x4       | Data                                             |
97
98 54 Maximilian Seesslen
h1. NMT
99 48 Maximilian Seesslen
100
h2. Actuator introduction
101
102
When introduction is requested by system command, each device must send an description.
103
104
|_. Size |_. Decription |_. Examples                                                       |
105
| 2      | Object       | Object                                                           |
106
| 6      | MAC/Unique ID| 48Bit                                                            |
107
108 52 Maximilian Seesslen
h3. Objects
109 53 Maximilian Seesslen
110 57 Maximilian Seesslen
|_. Size |_. Decription          |
111
|1       | Request intoruction   |
112
|2       | MAC low               |
113
|3       | MAC high              |
114
|4       | Protocol versions     |
115
|5       | Firmware version      |
116
|6       | Product Code          |
117
|7       | Node-Id               |
118
119 55 Maximilian Seesslen
120
h3. Protocol versions
121
122
|_. Size |_. Decription            |
123
|1       | TDT Major               |
124 56 Maximilian Seesslen
|1       | TDT Minor               |
125
|1       | NMT Major               |
126
|1       | NMT Minor               |
127
|1       | Blob Major              |
128
|1       | Blob Minor              |
129 55 Maximilian Seesslen
130 25 Maximilian Seesslen
131
h1. V2
132
133
|_. Size |_. Decription |_. Examples                                                       |
134
| 1      | Packet type  | Standard TDT packet                                              |
135
| 1      | Sub-Id;      | Futher index; Sub-Sensor or more specifi kind of thing to be set |
136
| 1      | Data type    | Int, Float, Time, Date, Percent, Promil, Multipacket-String      |
137 31 Maximilian Seesslen
| 1      | Unit         | Hz, °C, Time, Date, PWM, CAN-ID, Name, Description, Room         |
138 30 Maximilian Seesslen
| 4      | Value        | 32Bit                                                            |
139
140 1 Maximilian Seesslen
h2. Multimessage package
141
142
There should be the posssibillity to write the complete SPI-Flash even if it takes forever.
143
Not every slave needs to be able to send super big blocks. But every slave should be able to
144
send e.g. descriptions.