| 1 | 12 | Maximilian Seesslen | h1. Intro |
|---|---|---|---|
| 2 | 1 | Maximilian Seesslen | |
| 3 | 17 | Maximilian Seesslen | With the TDT-Protocol sensors can just send their values on the BUS without complex object catalogue. |
| 4 | An monitor-software is able to display values without knowing anything about the sensors or their configuration. |
||
| 5 | 46 | Maximilian Seesslen | The CANId cinsists of an function code and the node id. Like CANOpen the function code is 4 Bits and the Node-ID is 7 Bit. |
| 6 | In CAN2.0A there can only be 128 Nodes. |
||
| 7 | 1 | Maximilian Seesslen | |
| 8 | 35 | Maximilian Seesslen | CAN 2.0A: 0..0x7FF |
| 9 | CANOpen: 4 Bit Function code, 7 Bit Node-ID |
||
| 10 | Node-Id: 0..0x7F |
||
| 11 | 1 | Maximilian Seesslen | Function-Code Mask: 0x780 |
| 12 | 46 | Maximilian Seesslen | There are 14 or 28 Filters on STM32Fs |
| 13 | Some STM32 have an internal 96-bit unique ID. |
||
| 14 | 1 | Maximilian Seesslen | |
| 15 | 44 | Maximilian Seesslen | h2. Function code |
| 16 | |||
| 17 | 1 | Maximilian Seesslen | |_. Code |_. Decription |_. Examples | |
| 18 | 51 | Maximilian Seesslen | | 0x0 | NMT-Write | | |
| 19 | | 0x1 | NMT-Send | | |
||
| 20 | | 0x2 | Alarms | | |
||
| 21 | 44 | Maximilian Seesslen | | 0x6 | Write object | Set Date, illumination | |
| 22 | | 0x7 | Read object | Get product codes | |
||
| 23 | | 0x8 | Send object | Send temperature | |
||
| 24 | | 0x9 | data blob | | |
||
| 25 | 28 | Maximilian Seesslen | | 0xC | log | | |
| 26 | 1 | Maximilian Seesslen | |
| 27 | h1. IDs, ranges and commands |
||
| 28 | |||
| 29 | 46 | Maximilian Seesslen | h2. Node IDs |
| 30 | 1 | Maximilian Seesslen | |
| 31 | 44 | Maximilian Seesslen | * 11-Bit-Identifier, (CAN 2.0A); 2048; 0x0 ... 0x7F0; 0x0 ... 0x7F with function code |
| 32 | 1 | Maximilian Seesslen | * 29-Bit-Identifier, (CAN 2.0B); 0x20000000 |
| 33 | |||
| 34 | |_. Range |_. Decription |_. Examples | |
||
| 35 | | 0x01-0x0F | Network Manager | PC | |
||
| 36 | | 0x10-0x2F | Active controller | CANDis | |
||
| 37 | | 0x30-0x4F | Actor | CANSwitch | |
||
| 38 | 47 | Maximilian Seesslen | | 0x50-0x6F | Sending sensors | Sensemux, CANIO | |
| 39 | 1 | Maximilian Seesslen | | 0x70-0x7F | Passive Sensors | CANRec | |
| 40 | |||
| 41 | 45 | Maximilian Seesslen | h2. Object structutre |
| 42 | 1 | Maximilian Seesslen | |
| 43 | 44 | Maximilian Seesslen | |_. Size |_. Decription |_. Examples | |
| 44 | | 2 | Object | Plain Sensor value; Set illumination | |
||
| 45 | | 1 | Data type | Int, Float, Time, Date, Percent, Promil, Multipacket-String | |
||
| 46 | | 1 | Unit | Hz, °C, Time, Date, PWM, CAN-ID, Name, Description, Room | |
||
| 47 | | 4 | Value | 32Bit | |
||
| 48 | 36 | Maximilian Seesslen | |
| 49 | 44 | Maximilian Seesslen | h2. Objects |
| 50 | 36 | Maximilian Seesslen | |
| 51 | 44 | Maximilian Seesslen | |_. Code |_. Description | |
| 52 | | none | | |
||
| 53 | | ambientLight | | |
||
| 54 | | plantLight | | |
||
| 55 | | multimediaSwitch | | |
||
| 56 | | mainSwitch | | |
||
| 57 | | date | | |
||
| 58 | | time | | |
||
| 59 | | dummy | | |
||
| 60 | | plantSensor | | |
||
| 61 | | plantSensor0 | | |
||
| 62 | | plantSensor1 | | |
||
| 63 | | plantSensor2 | | |
||
| 64 | | plantSensor3 | | |
||
| 65 | | plantSensor4 | | |
||
| 66 | | firmwareVersion | | |
||
| 67 | | firmwareDate | | |
||
| 68 | | hardwareRevision | | |
||
| 69 | | hardwareDate | | |
||
| 70 | | temperatureIntern | | |
||
| 71 | | temperatureIntern1 | | |
||
| 72 | | temperatureIntern2 | | |
||
| 73 | | temperatureIntern3 | | |
||
| 74 | | temperatureIntern4 | | |
||
| 75 | | temperatureExtern | | |
||
| 76 | | temperatureExtern1 | | |
||
| 77 | | temperatureExtern2 | | |
||
| 78 | | temperatureExtern3 | | |
||
| 79 | | temperatureExtern4 | | |
||
| 80 | | humidity | | |
||
| 81 | | voc | | |
||
| 82 | 1 | Maximilian Seesslen | |
| 83 | 44 | Maximilian Seesslen | h2. Units |
| 84 | 17 | Maximilian Seesslen | |
| 85 | 44 | Maximilian Seesslen | * Date: year 2B, month 1B, day 1B |
| 86 | 1 | Maximilian Seesslen | * Time: hour 1B, minute 1B, second 1B, subsecond 1B |
| 87 | 17 | Maximilian Seesslen | |
| 88 | 46 | Maximilian Seesslen | h2. Example: Turn on the lights |
| 89 | 1 | Maximilian Seesslen | |
| 90 | 46 | Maximilian Seesslen | |_.Data |_.Size |_.Description | |
| 91 | |0x300 | 29 Bits | Function code: Write Object; All objects. | |
||
| 92 | |0x0 | 2 Byte | Message-Type: Global command | |
||
| 93 | |0x1 | 1 Byte | Data-Type: Permill | |
||
| 94 | |0x1 | 1 Byte | PWM: PWM permilli | |
||
| 95 | |1000 | 4 Byte | Value: Full Brightness | |
||
| 96 | |||
| 97 | 1 | Maximilian Seesslen | h1. Multipacket-Strings |
| 98 | |||
| 99 | 46 | Maximilian Seesslen | There should be the posssibillity to write the complete SPI-Flash even if it takes forever. |
| 100 | Not every slave needs to be able to send super big blocks. But every slave should be able to |
||
| 101 | send e.g. descriptions. |
||
| 102 | 15 | Maximilian Seesslen | |
| 103 | 46 | Maximilian Seesslen | |_. Size |_. Type | |
| 104 | | 0x4 | Package number (0: Data contains package count) | |
||
| 105 | | 0x4 | Data | |
||
| 106 | |||
| 107 | 25 | Maximilian Seesslen | |
| 108 | 1 | Maximilian Seesslen | h1. ID Assigning |
| 109 | 48 | Maximilian Seesslen | |
| 110 | h2. Actuator introduction |
||
| 111 | |||
| 112 | When introduction is requested by system command, each device must send an description. |
||
| 113 | |||
| 114 | |_. Size |_. Decription |_. Examples | |
||
| 115 | | 2 | Object | Object | |
||
| 116 | | 6 | MAC/Unique ID| 48Bit | |
||
| 117 | |||
| 118 | Objects: |
||
| 119 | 49 | Maximilian Seesslen | 1: Request intoruction |
| 120 | 2: Send MAC low |
||
| 121 | 3: Send MAC high |
||
| 122 | 50 | Maximilian Seesslen | 4: Send TDT Protocol version; |
| 123 | 5: Send Firmware version |
||
| 124 | 6: Write Node-Id |
||
| 125 | 48 | Maximilian Seesslen | |
| 126 | 25 | Maximilian Seesslen | |
| 127 | h1. V2 |
||
| 128 | |||
| 129 | |_. Size |_. Decription |_. Examples | |
||
| 130 | | 1 | Packet type | Standard TDT packet | |
||
| 131 | | 1 | Sub-Id; | Futher index; Sub-Sensor or more specifi kind of thing to be set | |
||
| 132 | | 1 | Data type | Int, Float, Time, Date, Percent, Promil, Multipacket-String | |
||
| 133 | 31 | Maximilian Seesslen | | 1 | Unit | Hz, °C, Time, Date, PWM, CAN-ID, Name, Description, Room | |
| 134 | 30 | Maximilian Seesslen | | 4 | Value | 32Bit | |
| 135 | |||
| 136 | 1 | Maximilian Seesslen | h2. Multimessage package |
| 137 | |||
| 138 | There should be the posssibillity to write the complete SPI-Flash even if it takes forever. |
||
| 139 | Not every slave needs to be able to send super big blocks. But every slave should be able to |
||
| 140 | send e.g. descriptions. |