1 | 12 | Maximilian Seesslen | h1. Intro |
---|---|---|---|
2 | 1 | Maximilian Seesslen | |
3 | 17 | Maximilian Seesslen | With the TDT-Protocol sensors can just send their values on the BUS without complex object catalogue. |
4 | An monitor-software is able to display values without knowing anything about the sensors or their configuration. |
||
5 | 24 | Maximilian Seesslen | The CANId of sensors is actually their configurable ID or an global command. |
6 | 1 | Maximilian Seesslen | |
7 | 17 | Maximilian Seesslen | Sensor values are ususally not very important so the CAN-IDs start at 0x200 (max ids 0x800); |
8 | |||
9 | 1 | Maximilian Seesslen | |_. Size |_. Decription |_. Examples | |
10 | 2 | Maximilian Seesslen | | 1 | Sub-Id; | Futher index; Sub-Sensor or more specifi kind of thing to be set | |
11 | 17 | Maximilian Seesslen | | 1 | Reserved | Maybe config-Flags; require Confirmation, is confirmation... | |
12 | | 1 | Data type | Int, Float, Time, Date, Percent, Promil, Multipacket-String | |
||
13 | | 1 | Unit | Hz, °C, Time, Date, PWM, CAN-ID, Name, Description, Room | |
||
14 | 1 | Maximilian Seesslen | | 4 | Value | 32Bit | |
15 | 2 | Maximilian Seesslen | |
16 | 28 | Maximilian Seesslen | h2. Values |
17 | |||
18 | * Date: year 2B, month 1B, day 1B |
||
19 | * Time: hour 1B, minute 1B, second 1B, subsecond 1B |
||
20 | |||
21 | 12 | Maximilian Seesslen | h2. Device behaviour |
22 | |||
23 | 1 | Maximilian Seesslen | All devices should shut down after 5 hours when no master-heartbeat is received. |
24 | |||
25 | h1. IDs, ranges and commands |
||
26 | 12 | Maximilian Seesslen | |
27 | 17 | Maximilian Seesslen | h2. CAN IDs |
28 | 29 | Maximilian Seesslen | |
29 | * 11-Bit-Identifier, (CAN 2.0A); 2048; 0x800 |
||
30 | * 29-Bit-Identifier, (CAN 2.0B); 0x20000000 |
||
31 | 2 | Maximilian Seesslen | |
32 | 1 | Maximilian Seesslen | |_. Range |_. Decription |_. Examples | |
33 | 10 | Maximilian Seesslen | | 0x010-0x0FF | Alarms | Devices have an issue | |
34 | 2 | Maximilian Seesslen | | 0x100-0x1FF | Control commands | Set global actuator | |
35 | | 0x200-0x2FF | Sensors/actors fixed | | |
||
36 | 9 | Maximilian Seesslen | | 0x300-0x6FF | Sensors/actors dynamic | | |
37 | | 0x6FF-0x7FF | Low priority boradcast | Power on devices | |
||
38 | |||
39 | 2 | Maximilian Seesslen | h2. Global actuator |
40 | |||
41 | 1 | Maximilian Seesslen | Global means that all actuators of an type is addressed and not one concrete partipiant. |
42 | 14 | Maximilian Seesslen | An specific partipiant can be specified when sending the target CAN-Id in the value. |
43 | 2 | Maximilian Seesslen | In this way the message is still high priority other than the "Remote Transmission Request" |
44 | |||
45 | 3 | Maximilian Seesslen | |_. ID |_. global actuator |_. Decription | |
46 | | 0x100 | System command | Perform system command; e.g. reboot, poweroff | |
||
47 | 6 | Maximilian Seesslen | | 0x101 | Date/Time | Set date/time of all actuator | |
48 | 8 | Maximilian Seesslen | | 0x102 | Illumination | Set brightness of lamps | |
49 | 1 | Maximilian Seesslen | | 0x103 | Powerswitch | Power on devices | |
50 | 14 | Maximilian Seesslen | | 0x104 | Plant watering pump | Automatically watering indoor plants | |
51 | 8 | Maximilian Seesslen | |
52 | 12 | Maximilian Seesslen | h2. System commands |
53 | 1 | Maximilian Seesslen | |
54 | |_. Sub-ID |_. Type | |
||
55 | 12 | Maximilian Seesslen | | 0x0 | Shutdown | |
56 | | 0x1 | Heartbeat | |
||
57 | |||
58 | h2. Illumination commands |
||
59 | |||
60 | 13 | Maximilian Seesslen | |_. Sub-ID |_. Type | |
61 | | 0x0 | Set ambient light | |
||
62 | | 0x1 | Get ambient light | |
||
63 | | 0x2 | Set ambient light, fading | |
||
64 | | 0x3 | Get ambient light, fading | |
||
65 | | 0x4 | Set plant light | |
||
66 | 1 | Maximilian Seesslen | | 0x5 | Get plant light | |
67 | |||
68 | h2. Powerswitch commands |
||
69 | |||
70 | |_. Sub-ID |_. Type | |
||
71 | | 0x0 | Set powerline for multimedia | |
||
72 | | 0x1 | Get powerline for multimedia | |
||
73 | 17 | Maximilian Seesslen | |
74 | |||
75 | h1. Multipacket-Strings |
||
76 | |||
77 | |_. Address |_. Type | |
||
78 | | 0x0 | Package count | |
||
79 | | 0x1 | Package number | |
||
80 | | 0x2..0x3 | Data | |
||
81 | |||
82 | h1. Actuator introduction |
||
83 | |||
84 | 1 | Maximilian Seesslen | When introduction is requested by system command, each device must send description for each subid. |
85 | 18 | Maximilian Seesslen | |
86 | h1. Example |
||
87 | |||
88 | 23 | Maximilian Seesslen | h2. Turn on the lights |
89 | |||
90 | 27 | Maximilian Seesslen | |_.Data |_.Size |_.Description | |
91 | |0x100 | 29 Bits | CAN-Id: Global command | |
||
92 | |0x0 | 1 Byte | Message-Type: Global command | |
||
93 | |0x0 | 1 Byte | Sub-Id: Set ambient light | |
||
94 | |0x1 | 1 Byte | Data-Type: Integer | |
||
95 | |0x1 | 1 Byte | PWM: PWM permilli | |
||
96 | |1000 | 4 Byte | Value: Full Brightness | |
||
97 | |||
98 | 15 | Maximilian Seesslen | |
99 | h1. Usecases |
||
100 | |||
101 | * simple actors can filter message to "Global actuator" messages, at least "system commands" |
||
102 | * There are 14 or 28 Filters on STM32Fs |
||
103 | 25 | Maximilian Seesslen | |
104 | h1. ID Assigning |
||
105 | |||
106 | Some STM32 have an internal 96-bit unique ID. |
||
107 | |||
108 | h1. V2 |
||
109 | |||
110 | |_. Size |_. Decription |_. Examples | |
||
111 | | 1 | Packet type | Standard TDT packet | |
||
112 | | 1 | Sub-Id; | Futher index; Sub-Sensor or more specifi kind of thing to be set | |
||
113 | | 1 | Data type | Int, Float, Time, Date, Percent, Promil, Multipacket-String | |
||
114 | | 1 | Unit | Hz, °C, Time, Date, PWM, CAN-ID, Name, Description, Room | |
||
115 | | 4 | Value | 32Bit | |
||
116 | |||
117 | h2. Multimessage package |
||
118 | |||
119 | |_. Size |_. Decription |_. Examples | |
||
120 | | 1 | Packet type | Multimessage package | |
||
121 | | 1 | count | Number of packages | |
||
122 | | 1 | number | 0: value=data length in bytes | |
||
123 | | 4 | Value | 32Bit | |
||
124 | |||
125 | |_. Size |_. Decription |_. Examples | |
||
126 | | 1 | Packet type | Multimessage package 2 | |
||
127 | | 1 | id | Mailbox | |
||
128 | | 1 | number | 0: value=data length in bytes | |
||
129 | | | | 1: value=number of messages | |
||