Projekt

Allgemein

Profil

Wiki » Historie » Version 6

Maximilian Seesslen, 11.04.2024 18:57

1 1 Maximilian Seesslen
h1. Wiki
2
3
4 soil moisture Sensors can be connected to the board.
4
The sensors can be evaluated one after the other.
5
6
With shrinking hose on the sensors, the values look quite stable.
7
Each sensor needs it calibration according to the type and cable.
8 3 Maximilian Seesslen
Air- and Water-Values are needed.
9
The reported value is promil; 0=Air and 1000=Water
10 1 Maximilian Seesslen
11
In raw mode, values are send in Hz, in normal mode, its send as permil.
12 6 Maximilian Seesslen
Cordyceps should also plot raw values in order to see if values are stable.
13
Change mode automatically? only show Hz in a field.
14 4 Maximilian Seesslen
15 1 Maximilian Seesslen
TDT-Commands:
16 2 Maximilian Seesslen
* Raw
17
* Calibrate dry
18 1 Maximilian Seesslen
* Calibrate water
19
* change sensor
20 6 Maximilian Seesslen
21
Calibration procedure:
22
* set to calibration via command
23
* Calibrate dry via command
24
* Calibrate water via command
25
* Reset via command