1 1 Maximilian Seesslen
h1. Eval
2
3 8 Maximilian Seesslen
Everything should be completely shut off when I'm not at home. Even clocks, displays, sensors.
4
5 1 Maximilian Seesslen
* Pressing On-button must switch 240V line
6
7
** Battery driven?
8
*** Will there be an plumbum battery or only regular powersupply
9
** A simple 1,5V Alkali will do.
10
** -Button can handle 240V-
11 2 Maximilian Seesslen
** An 18650 is perfect. Along with the MCP73871 or only MAX1811ESA+. No integrated LDO necessary, only SSR is switched. AUR9811DGD only 33 Cents.
12 4 Maximilian Seesslen
** An 18650 is way too big. We only flash the LED for a short time. Ne Knopfzelle wuerde es tun.
13 7 Maximilian Seesslen
** 2 AA-Alkali-batterien brauchen wieder Platz. So wenig stress wie die Knopfzelle im Miniminutnik macht. muesste ich wohl oefters die Industriezelle wechseln als die Knopfzelle.
14 1 Maximilian Seesslen
15 7 Maximilian Seesslen
* Single-Button can be realised by bringing signal to mosfet along with diodes. Dioden wegen Erhaltungsausgang. Zelle geht auf SSR, dann geht MCU-Ausgang auf SSR
16 1 Maximilian Seesslen
* Simple STM32F042 can be used
17
* Mini-USB connector for direct charge.
18 5 Maximilian Seesslen
* 5V AC/DC Wandler integrieren; 5W, >80% efficienty; Keine Schnelladestation, nur effiziente powerline.
19 6 Maximilian Seesslen
* Strom messen (Step 2); STM32-32K-Variante sinnvoll; sinnvoller wie Akku messen der eh bestromt wird wenn geraet eingeschalten ist.
20 3 Maximilian Seesslen
** Liegt altes Design noch wo rum?
21 5 Maximilian Seesslen
* USB A Buchsen; 1 Stueck on Board, Terminal fuer weitere 4 via Kabel
22 4 Maximilian Seesslen
* Timeout
23 5 Maximilian Seesslen
** Buzzer fuer intervention, startup, shutdown. Hab ja noch genug rumflitzen.