Solder » Historie » Version 17
Maximilian Seesslen, 21.10.2023 20:31
1 | 1 | Maximilian Seesslen | h1. Solder |
---|---|---|---|
2 | |||
3 | 15 | Maximilian Seesslen | * Techcon Dosiergerät TS-350, digital, 0-6,9 bar, 100-240 V |
4 | |||
5 | 4 | Maximilian Seesslen | h2. Dosiernadeln |
6 | |||
7 | 8 | Maximilian Seesslen | |_.Size |_.Diameter |_.Color | Form | Paste |_.Result | Time | In total | |
8 | |22 | 0,41mm | Blue | Plastik kegel | ? |To small, blocks | ? | | |
||
9 | |20 | 0.58mm | Pink | Plastik kegel | ? |To small, blocks | ? | | |
||
10 | |18 | 0.84mm | Green | Metall, gebogen | gestreckt |Laeuft super, etwas grob | ? | | |
||
11 | |20 | 0.58mm | Pink | Plastik kegel | gestreckt |gut... | 0,014 s | Some shortcuts | |
||
12 | |20 | 0.58mm | Pink | Plastik kegel | gestreckt |gut... | 0,013 s | lesser shortcuts | |
||
13 | |||
14 | h2. Reinigen |
||
15 | |||
16 | | Alkohol | | |
||
17 | 10 | Maximilian Seesslen | | 60min | General Flux is removed after scrubbing, still flux in parts with small pitch | |
18 | 8 | Maximilian Seesslen | |
19 | 13 | Maximilian Seesslen | | Ultraschall | | |
20 | | 5min pro Seite > 60°C | Still flux | |
||
21 | | +10min > 60°C | Minor Flux | |
||
22 | | +5min > 60°C | Nearly no Flux | |
||
23 | |||
24 | 17 | Maximilian Seesslen | | Ultraschall Only | | |
25 | | 30Min | Not very clean | |
||
26 | | 45Min | Quite ok, aber Lack schlaegt schon Blasen | |
||
27 | | 60Min | - | |
||
28 | 16 | Maximilian Seesslen | |
29 | 14 | Maximilian Seesslen | |
30 | h2. Loepaste strecken |
||
31 | |||
32 | * ULF-10: Viel dreck, aber funktioniert nach putzen; verstopft nicht |
||
33 | * AGT-038: Loetresultat super; verstopft aehnlich aber nur in spitze (pink) |